Design#
Networks#
The pypsa.Network
is an overall container for all network components.
Components cannot exist without a network.
It also holds functions to run compute power flows, optimal power flow and capacity expansion planning problems, as well as functions to retrieve statistics and plot the network.
Buses#
The bus is the fundamental node to which all loads, generators, storage units, lines, transformers and links attach. You can have as many components attached to a bus as you want. The bus’s role is to enforce energy conservation for all elements feeding in and out of it (i.e. like Kirchhoff’s Current Law).
Energy flows#
Energy enters the model in generators, storage units or stores with higher energy before than after the simulation, and any components with efficiency greater than 1 (e.g. heat pumps).
Energy leaves the model in loads, storage units or stores with higher energy after than before the simulation, and in lines, links or storage units with efficiency less than 1.
Data storage#
To enable efficient calculations on the different dimensions of the
data, data is stored in memory using pandas.DataFrame
objects.
To see which data is stored for each component, see Components.
Static data#
For each component type (line, transformer, generator, etc.), which must be
uniquely named for each network, its basic static data is stored in a
pandas.DataFrame
, which is an attribute of the pypsa.Network
, with names
that follow the component names:
n.buses
n.generators
n.loads
n.lines
n.links
n.storage_units
n.stores
n.transformers
The columns contain data such as impedance, capacity, costs, efficiencies and
the buses to which components are attached. All attributes for each component
type are listed with their properties (defaults, etc.) in
Components and are accessible from the network object, e.g.
in n.components["Bus"]["attrs"]
.
Time-varying data#
Some quantities, such as generator p_max_pu
(generator availability),
generator p
(generator calculated active power), line p0
(line active
power at bus0
) and line p1
(line active power at bus1
) may vary over
time, so different values of these attributes for the different snapshots
(n.snapshots
) are stored in the following attributes of the network object:
n.buses_t
n.generators_t
n.loads_t
n.lines_t
n.links_t
n.storage_units_t
n.stores_t
n.transformers_t
These are dictionaries of pandas.DataFrame
objects, so that for example
n.generators_t["p_set"]
is a pandas.DataFrame
with columns
corresponding to generator names and index corresponding to
n.snapshots
. You can also access the dictionary like an
attribute n.generators_t.p_set
.
Time-varying data are marked as series
in the listings in Components.
For input data such as p_max_pu
of a generator you can store the
value statically in n.generators
if the value does not
change over n.snapshots
or you can define it to be
time-varying by adding a column to n.generators_t.p_max_pu
. If
the name of the generator is in the columns of
n.generators_t.p_max_pu
, then the static value in
n.generators
will be ignored. Some example definitions of
input data:
import pypsa
n = pypsa.Network()
#four snapshots are defined by integers
n.set_snapshots(range(4))
n.add("Bus", "my bus")
#add a generator whose output does not change over time
n.add("Generator", "Coal", bus="my bus", p_set=100)
#add a generator whose output does change over time
n.add("Generator", "Wind", bus="my bus", p_set=[10,50,20,30])
In this case only the generator “Wind” will appear in the columns of
n.generators_t.p_set
.
For output data, all time-varying data affecting generators is stored in the
n.generators_t
dictionaries, but it is only defined once a computation has
been run.
Unit Conventions#
The units for physical quantities are chosen for easy user input.
The units follow the general rules:
Quantity |
Units |
---|---|
Power |
MW/MVA/MVar (unless per unit of nominal power, e.g. generator.p_max_pu for variable generators is per unit of generator.p_nom) |
Time |
h |
Energy |
MWh |
Voltage |
kV phase-phase for bus.v_nom; per unit for v_mag_pu, v_mag_pu_set, v_mag_pu_min etc. |
Angles |
radians, except transformer.phase_shift which is in degrees for easy input |
Impedance |
Ohm, except transformers which are pu, using transformer.s_nom for the base power |
CO2-equivalent emissions |
tonnes of CO2-equivalent per MWh_thermal of energy carrier |
Per unit values of voltage and impedance are used internally for network calculations. It is assumed internally that the base power is 1 MVA. The base voltage depends on the component.
Sign Conventions#
The sign convention in PyPSA follows other major software packages, such as MATPOWER, PYPOWER and DIgSILENT PowerFactory.
The power (p,q) of generators or storage units is positive if the asset is injecting power into the bus, negative if withdrawing power from bus.
The power (p,q) of loads is positive if withdrawing power from bus, negative if injecting power into bus.
The power (p0,q0) at bus0 of a branch (line, link, or transformer) is positive if the branch is withdrawing power from bus0, i.e. bus0 is injecting into branch
Similarly the power (p1,q1) at bus1 of a branch is positive if the branch is withdrawing power from bus1, negative if the branch is injecting into bus1
If p0 > 0 and p1 < 0 for a branch then active power flows from bus0 to bus1; p0+p1 > 0 is the active power losses for this direction of power flow.
Input and output data#
Input and output data is strictly separated in PyPSA, such that inputs are not overwritten by outputs from computations. Therefore, set points are stored separately from actual dispatch points.
For instance, dispatchable generators have a p_set
series which is separate
from the calculated active power series p
, since the operators’s intention
may be different from what is calculated (e.g. when using distributed slack for
the active power).